Elabscience
QuicKey Pro Mouse IgA (Immunoglobulin A) ELISA Kit
- SKU:
- E-OSEL-M0007
- Weight:
- 0 KGS
- Shipping:
- Calculated at Checkout
Description
QuicKey Pro Series
Get more sensitive and precise results with saving at least 1-2h comparing to traditional ELISA Kits. The new developed technology in house will help to accelerate your science research in a more efficient way.
Product Details
Properties
| Assay type | Sandwich-ELISA |
| Format | 96T/48T/24 |
| Assay time | 1.5h |
| Detection range | 1.56-100 ng/mL |
| Sensitivity | 0.94 ng/mL |
| Sample type &Sample volume | serum and plasma; 50μL |
| Specificity | This kit recognizes IgA in samples. No significant cross-reactivity or interference between IgA and analogues was observed. |
| Reproducibility | Both intra-CV and inter-CV are < 10%. |
| Application | This ELISA kit applies to the in vitro quantitative determination of IgA concentrations in serum and plasma. |
Test Principle
Kit components & Storage
| Item | Specifications | Storage |
|---|---|---|
| Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips 48T: 8 wells ×6 strips 24T: 8 wells ×3 strips 96T*5: 5 plates, 96T |
2-8℃, 1 months |
| Reference Standard | 96T: 2 vials 48T/24T: 1 vial 96T*5: 10 vials |
2-8℃, use the reconstituted standard within 24h |
| Concentrated HRP Linked Detection Ab(100×) | 96T: 1 vial, 60 μL 48T/24T: 1 vial, 30 μL 96T*5: 5 vials, 60 μL |
2-8℃(Protect from light) |
| Reference Standard & Sample Diluent | 96T/48T/24T: 1 vial, 20 mL 96T*5: 5 vials, 20 mL |
2-8℃ |
| HRP Linked Ab Diluent | 96T/48T/24T: 1 vial, 14 mL 96T*5: 5 vials, 14 mL |
|
| Concentrated Wash Buffer(25×) | 96T/48T/24T: 1 vial, 30 mL 96T*5: 5 vials, 30 mL |
|
| Substrate Reagent | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃(Protect from light) |
| Stop Solution | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃ |
| Plate Sealer | 96T/48T/24T: 5 pieces 96T*5: 25 pieces |
|
| Product Description | 1 copy | |
| Certificate of Analysis | 1 copy |
Technical Data
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level IgA were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level IgA were tested on 3 different plates, 20 replicates in each plate.
| Intra-assay Precision | Inter-assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean (ng/mL) | 5.31 | 10.82 | 37.83 | 5.54 | 11.76 | 34.39 |
| Standard deviation | 0.34 | 0.51 | 1.97 | 0.39 | 0.70 | 1.60 |
| CV (%) | 6.45 | 4.67 | 5.22 | 6.99 | 5.94 | 4.66 |
Recovery
The recovery of IgA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
| Sample Type | Range (%) | Average Recovery (%) |
|---|---|---|
| Serum(n=8) | 93-104 | 99 |
| EDTA plasma(n=8) | 91-104 | 98 |
Linearity
Samples were spiked with high concentrations of Mouse IgA and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Additional Information
Reactivity: |
Mouse |
Detection Range: |
1.56~100 ng/mL |
Sensitivity: |
0.94 ng/mL |