Elabscience

QuicKey Pro Human IGF-1 (Insulin-like Growth Factor 1) ELISA Kit

(No reviews yet) Write a Review
SKU:
E-OSEL-H0012
Weight:
0 KGS
Shipping:
Calculated at Checkout
  • QuicKey Pro Human IGF-1(Insulin-like Growth Factor 1) ELISA Kit
  • QuicKey Pro Human IGF-1(Insulin-like Growth Factor 1) ELISA Kit
  • QuicKey Pro Human IGF-1(Insulin-like Growth Factor 1) ELISA Kit
  • QuicKey Pro Human IGF-1(Insulin-like Growth Factor 1) ELISA Kit
€295.00 - €776.00

Description

QuicKey Pro Series

Get more sensitive and precise results with saving at least 1-2h comparing to traditional ELISA Kits. The new developed technology in house will help to accelerate your science research in a more efficient way.

Product Details

Properties

Assay type Sandwich-ELISA
Format 96T/48T/24
Assay time 1.5h
Detection range 3.12-100 ng/mL
Sensitivity 1.01 ng/mL
Sample type &Sample volume serum and plasma; 50μL
Specificity This kit recognizes IGF-1 in samples. No significant cross-reactivity or interference between IGF-1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are < 10%.
Application This ELISA kit applies to the in vitro quantitative determination of IGF-1 concentrations in serum and plasma.

Test Principle

This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human IGF-1. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Human IGF-1 are added to the micro ELISA plate wells. Human IGF-1 in samples (or standards) combines with the coated antibody and HRP linked detection antibody specific to IGF-1. Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450±2 nm. The concentration of Human IGF-1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Kit components & Storage

An unopened kit can be stored at 2-8℃ for 6 months. After test, the unused wells and reagents should be stored according to the table.
Item Specifications Storage
Micro ELISA Plate(Dismountable) 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips
24T: 8 wells ×3 strips
96T*5: 5 plates, 96T
2-8℃, 1 months
Reference Standard 96T: 2 vials
48T/24T: 1 vial
96T*5: 10 vials
2-8℃, use the reconstituted standard within 24h
Concentrated HRP Linked Detection Ab(100×) 96T: 1 vial, 60 μL
48T/24T: 1 vial, 30 μL
96T*5: 5 vials, 60 μL
2-8℃(Protect from light)
Reference Standard & Sample Diluent 96T/48T/24T: 1 vial, 20 mL
96T*5: 5 vials, 20 mL
2-8℃
HRP Linked Ab Diluent 96T/48T/24T: 1 vial, 14 mL
96T*5: 5 vials, 14 mL
 
Concentrated Wash Buffer(25×) 96T/48T/24T: 1 vial, 30 mL
96T*5: 5 vials, 30 mL
Substrate Reagent 96T/48T/24T: 1 vial, 10 mL
96T*5: 5 vials, 10 mL
2-8℃(Protect from light)
Stop Solution 96T/48T/24T: 1 vial, 10 mL
96T*5: 5 vials, 10 mL
2-8℃
Plate Sealer 96T/48T/24T: 5 pieces
96T*5: 25 pieces
 
Product Description 1 copy
Certificate of Analysis 1 copy

Technical Data

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level IGF-1 were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level IGF-1 were tested on 3 different plates, 20 replicates in each plate.

  Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (ng/mL) 108.85 204.73 939.71 108.24 188.86 876.39
Standard deviation 6.29 9.87 28.76 6.30 11.05 41.80
CV (%) 5.78 4.82 3.06 5.82 5.85 4.77

Recovery

The recovery of IGF-1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 92-103 97
EDTA plasma(n=8) 90-104 95

Linearity

Samples were spiked with high concentrations of Human IGF-1 and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Target Information

Database Links SwissProt: P05019
Synonyms insulin-like growth factor 1,IGF1
Research Area Cancer, Developmental biology, Signal transduction
View AllClose

Additional Information

Reactivity:
Human
Detection Range:
3.12~100 ng/mL
Sensitivity:
1.01 ng/mL
View AllClose